This Question is Answered

1 "correct" answer available (10 pts) 2 "helpful" answers available (5 pts)
2,291 Views 4 Replies Last post: Jan 14, 2009 7:10 AM by friederikedeaquino RSS
friederikedeaquino Novice 3 posts since
Jan 14, 2009
Currently Being Moderated

Jan 14, 2009 1:58 AM

Is it possible to change the default system SERIAL number 987654-32-0 in Netapp simulator ? (I know how to change the system ID)

I have installed two Ontap 7.2.1 simulators called sim1 and sim2 on one RedHat Linux Ent 4 server but both simulators list the same SYSTEM serial number (the sysconfig command confirms that both use System Serial Number: 987654-32-0)

 

I need to demonstrate customers the use of the Veritas Storage Foundation Suite for Windows (SFW) DMP DSM multipathing option for servers that are attached via ISCSI to TWO different Netapp Filers. SFW lists unfortunately the disks from both sim1 and sim2 under the same array/filer name = 'NETAPP LUN 987654-32-0' . SFW does not use the System ID or ISCSI Target ID to identify different Netapp Filers but the System Serial Number.  My demonstration will not work when both virtual netapp filers have the same system serial number as I want to demonstrate different array settings for each array which cannot be done if both filers are shown as one array/filer.

 

I need in total only two different System Serial Number (one for each of the two simulators).

 

Note:

a) I know that you can change the System ID by editing the ,serialno file but I can't find this option for the System Serial number.

b) I have also assigned a different ISCSI target ID to each simulated Netapp filer.

c) I believe the System serial number has been hardcoded by Netapp in the maytag.L. 

Is there anything that can be done to change it?

 

Thank you very much for your help!

 

Freddy

tomas_netherlands Enthusiast 36 posts since
Nov 5, 2008

You might want to try a different version of the simulator (eg 7.2.4l1 ) Maybe this one has a different serial number?

 

Tomas

nagendrk NetApp Employee Master 225 posts since
Mar 29, 2008

Try this...

 

Stop the simulator.  Create a new file ",sys-serial-num" in the same directory as maytag executable.  As the first line, type the serial number desired.  Start the simulator.